Home > Ball Valves > 2Way Metal Ball Valves Screwed & Flanged End > 2390F |
| |
|
2-Way Full Port, Ball Valve, 2-Piece design with Pneumatic Rotary Actuator |
DATA SHEET
2390 F |
|
| |
|
AVCON produces 2-piece Ball Valves with ISO 5211 mounting pad. The valves are provided with mounting bracket, couplers for fitting Pneumatic Rotary Actuators, either Double Acting or Spring Return type. (For Pneumatic Actuator details, Please refer to AVCON leaflet 3400-D/S or 3300-D/S or 3600-D/S). The Flanged end valves having face to face dimensions as per DIN 3202-1-1984; Also EN 558-1995. Model 3400 Pneumatic Actuators having Namur mounting interface, are available with AVCON Namur 5-way, 2-Position Solenoid Valves type 9484E, 9384E,9485E, 9385E. Other Pneumatic Actuators can be also provided with Namur mounted Solenoid Valve facility.
| SPECIFICATIONS |
| Sizes |
15 mm (1/2”) to 150 mm (6”). |
| Body and End Piece |
Investment Casted Cast Steel
ASTM A 216 WCB (DIN 1.0619 GS-C 25) or Stainless
Steel ASTM A351 CF8 (DIN1. 4301) or CF8M (DIN1.4408) (GX6 Cr.NI MO1810). |
| Ball |
Stainless Steel AISI 316. |
| Design |
As per API 607 Std. Fire Safe
(but not tested). |
| Stem and stem nut |
Stainless Steel AISI 316. |
| Ball seat |
Reinforced PTFE. |
| Stem seals |
Reinforced PTFE. |
| Body gasket |
PTFE. |
| Antistatic device |
Stainless Steel SS316. |
| Pressure-temperature rating |
As per BS 5351 Class 300. |
| Body pressure rating |
ANSI B16.5 Class 300. |
| End connection |
Flanged to ANSI B16.5 Class
150. |
| Leakage Class |
As per ANSI B16.104 1976
Teflon seating Class VI. |
| Characteristics |
On-Off. |
| Temperature |
Continuoust 180 °C. |
| |
Intermittent 200°C. |
| ACTUATOR |
| Double Acting |
"D" - NC/NO. |
| Spring Return |
"S" - NC/NO. |
| Air supply requirement |
4 to 8.5 bar. (Line fluid pressure dependent). |
|
 |
| |
| Manual operation (Optional) |
Provision for manual Hand-lever type for 3403 & 3404-D/S actuator. Manual Hand Gear operated for 3305 & 3605-D/S
onward. |
| Accessories |
Local position indicator, Rotary Limit switch box, Air Lock Relay Solenoid Valves, Valve Positioner, etc. |
| Sales point |
Highly reliable,long life, Simple in construction and maintenance free Ball Valve. |
| Application |
For air, water, oil, gas, corrosive Chemicals, Combustion equipment, Power Stations, Hydro-Electric, Power Generation, Chemicals & Petrochemicals Industries, Water treatment plants. RO Plants, etc. |
|
| |
Catalog
Number |
Size |
Orifice
Size
(mm) |
Flow
Factor
Kv |
Body
Test
Pressure |
Working
Pressure |
Actuator Type |
Open Time
(Approx). |
Air Consumption (litres) |
| S |
D |
Secs. |
S |
D |
| |
Inch |
m |
mm |
m3/ h |
bar |
bar |
Spring Return* |
Double |
S |
D |
Open |
Close |
Open |
Close |
| 2390 F 155 |
½ |
15 |
15 |
10.40 |
40 |
12 |
3403 |
3403 |
0.40 |
0.50 |
0.30 |
- |
0.30 |
0.30 |
| 2390 F 205 |
3/4 |
20 |
20 |
27.52 |
40 |
12 |
3403 |
3403 |
0.40 |
0.50 |
0.30 |
- |
0.30 |
0.30 |
| 2390 F 255 |
1 |
25 |
25 |
48.00 |
40 |
12 |
3404/ 3304/ 3604 |
3404/ 3304 / 3604 |
0.60 |
0.60 |
1.10 |
- |
1.10 |
1.40 |
| 2390 F 405 |
1½ |
40 |
40 |
103.00 |
40 |
12 |
3404/ 3304/ 3604 |
3404/ 3304 / 3604 |
0.60 |
0.60 |
1.10 |
- |
1.10 |
1.40 |
| 2390 F 505 |
2 |
50 |
50 |
206.00 |
40 |
12 |
3305/ 3605 |
3305/ 3605 |
6.00 |
1.65 |
2.00 |
- |
2.00 |
2.50 |
| 2390 F 655 |
2½ |
65 |
65 |
275.00 |
40 |
12 |
3306/ 3606 |
3305/ 3605 |
6.00 |
1.65 |
6.00 |
- |
2.00 |
2.50 |
| 2390 F 805 |
3 |
80 |
80 |
498.00 |
40 |
12 |
3306/ 3606 |
3306/ 3606 |
6.00 |
1.65 |
6.00 |
- |
6.00 |
7.00 |
| 2390 F 1005 |
4 |
100 |
100 |
875.00 |
40 |
12 |
3307/ 3607 |
3306/ 3606 |
9.00 |
6.00 |
13.00 |
- |
6.00 |
7.00 |
| 2390 F 1505 |
6 |
150 |
150 |
2297.00 |
40 |
12 |
3308/ 3608** |
3308/ 3608** |
9.00 |
9.00 |
19.00 |
- |
19.00 |
23.00 |
** Minimum Pressure Required is 6 bar. *Actuator when with Namur Solenoid Value |
|
|
 |
| BILL OF MATERIAL |
| ITEM |
PARTS |
MATERIAL |
ITEM |
PARTS |
MATERIAL |
| 1 |
BODY |
Refer Note no. 1* |
12 |
BUSH GLAND |
S.S.AISI.304 |
| 2 |
STEM |
S.S.AISI.316 |
13 |
BUSHING |
RPTFE |
| 3 |
STEM SEAL |
RPTFE |
14 |
BELLEVILLE WASHER |
S.S.AISI.301 |
| 4 |
BALL |
Refer Note no. 1* |
15 |
LOCK WASHER |
S.S.AISI.304 |
| 5 |
SEAT |
PTFE |
16 |
LOCK NUT |
S.S.AISI.304 |
| 6 |
FLAT RING |
PTFE |
17 |
BRACKET |
Refer Note no. 2* |
| 7 |
END PIECE |
Refer Note no. 1* |
18 |
ADAPTOR |
| 8 |
BOLTS/STUDS |
Refer Note no. 3* |
19 |
SPRING WASHER |
Refer Note no. 3* |
| 9 |
SPRING WAHSER |
20 |
HEX.BOLT |
| 10 |
HEX.NUT |
21 |
ACTUATOR |
3400-D/S, 3300-D/S, 3600-D/S |
| 11 |
GLAND PACKING |
PTFE |
|
|
|
|
| This bill of Material is for St. St. Body Valves. |
| |
| DIMENSIONS IN (MM) FOR FULL PORT VALVE WITH PNEUMATIC ACTUATOR |
Catalogue
Number |
Valve Size |
A5 |
B |
C |
D1 |
D |
E |
Weight (Approx).Kgs. |
| inch |
mm |
S |
D |
S |
D |
S |
D |
S |
D |
| 2390 F 155 |
1/2 |
15 |
108 |
45 |
200 |
200 |
150 |
120 |
64 |
64 |
2.80 |
2.60 |
| 2390 F 205 |
3/4 |
20 |
118 |
49 |
205 |
205 |
150 |
120 |
64 |
64 |
3.20 |
3.00 |
| 2390 F 255 |
1 |
25 |
127 |
54 |
237 |
237 |
188 |
140 |
88 |
88 |
5.23 |
4.16 |
| 2390 F 405 |
1½ |
40 |
165 |
64 |
252 |
252 |
188 |
140 |
88 |
88 |
7.80 |
7.00 |
| 2390 F 505 |
2 |
50 |
178 |
76 |
292 |
292 |
188 |
188 |
104 |
104 |
10.75 |
10.35 |
| 2390 F 655 |
2½ |
65 |
190 |
89 |
367 |
306 |
276 |
188 |
157 |
104 |
20.00 |
12.00 |
| 2390 F 805 |
3 |
80 |
203 |
96 |
378 |
378 |
276 |
276 |
157 |
157 |
32.00 |
30.80 |
| 2390 F1005 |
4 |
100 |
229 |
115 |
467 |
400 |
356 |
276 |
214 |
157 |
59.00 |
42.00 |
| 2390 F1505 |
6 |
150 |
394 |
139.5 |
620 |
620 |
400 |
400 |
276 |
276 |
112.00 |
101.80 |
|
|
| * Open Tolerance ±3 all over, A5 = Flanged ends D= Double Acting, D1 = Single Acting/ Spring Return. |
| |
| Note: 1. Bodies are Investment casted in ASTM A216 WCB, ASTM A351-CF8 or CF8M. |
| 2. Brackets and Adapters are Investment casted in WCB. As an optional can be supplied with CF8 material. |
| 3. Bolts / studs, hex nuts material are supplied in ASTM-A - 193-B7 & B8. |
| Note: |
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON. |
| |
|
|
|
|
|
|
|
|
|