Home > Pneumatic On/Off Valves > Pneumatic Cylinder Valves > 6616E-6619E |
|
| |
3/2-Way Pneumatic Piston Operated
Mixing or Diverting Valves
With Cylinder Actuator, For On-Off Application
(Rust Free Design) |
DATA SHEET
6616E-NORMALLY
‘A’ PORT CLOSED
6619E-NORMALLY
‘B’
PORT CLOSED |
|
| |
|
| SPECIFICATIONS : |
| Size |
15 mm (1/2”) to 50 mm (2”). |
| CONSTRUCTION : |
| Body and Bonnet |
Investment casted ASTM-A,
351CF8 (St.St. 304) CF8M
(St.St. 316). |
| Pressure Temperature Rating |
As per ANSI class 300. |
| End Connections |
Standard BSP(F)/ NPT(F). |
| Seating |
Soft seated Teflon backed by
EPDM. Optional-VITON/ EPDM,
Buna Nitrile. |
| Leakage |
As per ANSI B16.104 - 1976
Teflon seating class IV. For other
soft seating class VI Drop Tight/ Bubble Tight. |
| Trim |
S.S. AISI 304/316. |
| Stem Packing |
Self adjusting, Spring loaded
Teflon packing. |
| Characteristics |
On-off, normally closed/ normally
open. |
| Working Fluid Pressure |
Refer to table below. |
| Working Temperature |
On steam-continuous 155°C,
Intermittent 180°C with Teflon
seating, Buna Nitrile 80°C,
EPDM 135°C, VITON 180°C. |
| ACTUATOR |
| Spring return type, Pneumatic Cylinder. |
| Cylinder Cover |
S.S. AISI 304 (deep drawn). |
| Cylinder Flange |
Pressure die casted, aluminium
silicon alloy, solution treated and
hard anodised. |
| Piston |
Steel (deep drawn). |
| Piston Packing |
Buna Nitrile |
| Actuator Spring |
IS 4454 Grade III, duly painted. |
Actuator Working
Signal Pressure |
3.5 to 6 bar, (refer to graph). |
| Operating Cycles per hour |
15mm, 20mm, 25mm upto 600 cy/hr. 35mm and 50mm upto 300
cy/hr. (tested on air, on other
fluids, this figure may vary). |
|
 |
| Life Expectancy |
Over one million cycles (lab
tested in ideal condition) |
| Air Quality |
Lubricated/Non-lubricated. |
| Maximum Operating Pressure Differential |
Refer to graph. |
| Accessory |
Position indicating limit
switch box, solenoid valve, filter
regulator gauge. Other accessories
available on application. |
| Application |
For control of air, water, oil, gas,
steam in textile, power generation,
paper & pulp,
chemical, petro chemical
industries, PSA nitrogen system,
air dryer, gas generator and in
process plants. |
| Back Pressure |
Refer to table below or 2.5 bar. |
| Instruction Manual |
Refer to IM 6616E/6619E. |
|
|
| |
| SPECIFICATION TABLE |
Catalogue
Number |
Size
BSP (F) |
Orifice Size |
Flow Factor Kv |
*Maximum
Working Pressure |
Safe Working
Pressure |
Actuator Type |
Air
Consumption |
| Inch |
mm |
mm |
m³/hr |
bar |
bar |
Cy |
litres/cy. |
6616 E 15
6619 E 15 |
1/2 |
15 |
15 |
3.3 |
10 |
16 |
70 |
0.150 |
6616 E 20
6619 E 20 |
3/4 |
20 |
18 |
4.7 |
10 |
16 |
70 |
0.150 |
6616 E 25
6619 E 25 |
1 |
25 |
23 |
8.5 |
10 |
16 |
70 |
0.160 |
6616 E 35
6619 E 35 |
1½ |
35 |
36 |
22.5 |
10 |
16 |
100 |
0.310 |
6616 E 50
6619 E 50 |
2 |
50 |
45 |
35.0 |
7 |
16 |
100 |
0.326 |
|
| * Inlet Pressure at ‘A’ port or ‘B’ port. |
 |
|
OPERATION :
Valve Type 6616E - In normal
condition, ‘A’ port is closed and
‘AB’ port is connected to ‘B’ or
‘B’ port is connected to ‘AB’ port.
on receiving pilot pressure, ‘A’
port is connected to ‘AB’ or ‘AB’
port is connected to ‘A’ closing
port B.
Valve Type 6619E - Normally
‘B’ port is closed and ‘A’ port is
connected to ‘AB’ or ‘AB’ port is
connected to ‘A’. On receiving
signal ‘A’ port is closed and ‘B’
port is connected to ‘AB’ or ‘AB’
port connected to ‘B’. |
Mixing :
Valves can be used for introducing
two different fluids (mixing)
through two different ports to
common port ‘AB’.
Diverting :
One fluid coming through port ‘AB’
can be diverted to ‘A’ port or ‘B’
port. |
 |
| DIMENSIONS (IN MM) |
CATALOGUE
NUMBER |
SIZE |
A |
B |
C |
D |
WEIGHT
(Kgs) |
| Inch |
mm |
6616 E 15
6619 E 15 |
1/2 |
15 |
85 |
50 |
185 |
103.5 |
2.275 |
6616 E 20
6619 E 20 |
3/4 |
20 |
110 |
66 |
194 |
103.5 |
3.000 |
6616 E 25
6619 E 25 |
1 |
25 |
120 |
72 |
204 |
103.5 |
3.500 |
6616 E 35
6619 E 35 |
1½ |
35 |
150 |
91 |
285 |
138.0 |
8.750 |
6616 E 50
6619 E 50 |
2 |
50 |
190 |
100 |
292 |
138.0 |
12.750 |
| * OPEN TOLERANCE ± 3 mm ALL OVER |
|
|
| |
 |
| |
| Note: |
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON. |
| |
|
|
|
|
|
|
|
|