Home

About Us

Products Newsletter Offshore Capabilities Downloads Contact Us
    Products l Back  
    3/2 Way Pneumatic Diaphragm Operated Normally Closed Valves
Screwed Female End Type Body For High Duty,
On-Off, Mixing or Diverting Application.


DATA SHEET
7416B
   
SPECIFICATION :
Size 15 mm (½”) to 50 mm (2")
 
CONSTRUCTION :
Body and End Piece Investment Casted ASTM-A,
351CF8 (St.St. 304)/CF8M
(St.St. 316)
Pressure Temperature Rating As per ANSI class 300.
End Connections Standard BSP(F)/NPT(F) or
Socket Weld.
Seating Metal to Metal backed by
specially compounded Teflon.
Leakage As per ANSI B16.104 - 1976
Trim (Spindle) S.S. AISI 400/S.S. hard chrome
plated.
Stem Packing Self adjusting, spring loaded
Teflon packing.
Characteristics On-off, normally closed.
Working Fluid Pressure Refer to table below.
Working Temperature On steam - continuous 180°C
Intermittent 205°C.
 
ACTUATOR :
Spring return type, high duty Pneumatic Diaphragm
Actuator.
Diaphragm Cover Sheet metal pressing.
Diaphragm Nylon inserted Neoprene
Bottom Cover High duty cast iron.
Yoke ASTM. A216 WCB Investment
casted
Actuator Spring IS 4454 Grade III, duly painted.
Actuator Working 2 to 3.5 bar
Operating Cycles per hour 15mm, 20mm, 25mm upto 800
cy/hr. 35 mm and 50mm upto 300
cy/hr (tested on air, on other
fluids, this figure may vary).
Life Expectancy Over one million cycles (lab tested in ideal condition).

Air Quality Dry air or non corrosive gas.
Accessory Air lock, Solenoid Valve, Filter
Regulator Gauge. Other
accessories available on
application.
Application For control of air, water, oil, gas,
steam, hydraulic oil.
specially where heavy duty
operations are called for,
specially on tyre and tube
building presses, power
generation, atomic energy,
chemical & petrochemical plant,
PSA nitrogen system, air and
gas dryers, gas generators and
others.
Back Pressure Refer to AVCON.
Instruction Manual Refer to 1M 7416B.
 
SPECIFICATION TABLE
Catalogue
Number

Size
BSP(F)

Orifice
Size
Flow Factor
Kv
Maximum Working Pressure Safe Working
Pressure
Actuator
Type
Air
Consumption
Air/Gas Hot Water Steam
Inch mm mm M³ /hr. Bar Bar Bar bar Litres/cy
7416B15 ½ 15 13 2.8 21 16 16 42 450A 0.150
7416B20 3/4 20 15 4.3 21 16 16 42 550A 0176
7416B25 1 25 19 7.0 21 16 16 42 550C 0.471
7416B35 1 ½ 35 34 22.7 21 16 16 42 550D 0.966
7416B50 2 50 45 36.0 21 16 16 42 550D 0.966
 
1
 
OPERATION :
Valve Type 7416B -Normally ‘A’ port is closed
and ‘B’ port is connected to ‘AB’ or ‘AB’ port is
connected to ‘B’.On receiving signal ‘B’ port is
closed and ‘A’ port is connected to ‘A’ or ‘AB’
port is connected to ‘A’.
Mixing :
Valves can be used for introducing two different
fluids (mixing) through two different ports to
common port ‘AB’.
Diverting :
One fluid coming through port ‘AB’ can be
diverted to ‘A’ port or ‘B’ port.
DIMENSIONS ( IN MM )
Catalogue
Number
Size A B C ØD Weight Kgs
Inch mm
7416B15 ½ 15 85 50 166 165 2.750
7416B20 3/4 20 110 66 200 184 6.350
7416B25 1 25 120 72 250 241 10.750
7416B35

1 ½

35 150 91 310 300 18.000
7416B50 2 50 190 100 432 300 24.500

•OPEN TOLERANCE ± 3MM ALL OVER.

FLOW DIAGRAMS
Note:
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON.
   
Products l Back
   