Metal to Metal backed by
specially compounded Teflon.
Leakage
As per ANSI B16.104 - 1976
Trim (Spindle)
S.S. AISI 400/S.S. hard chrome
plated.
Stem Packing
Self adjusting, spring loaded
Teflon packing.
Characteristics
On-off, normally closed.
Working Fluid Pressure
Refer to table below.
Working Temperature
On steam - continuous 180°C
Intermittent 205°C.
ACTUATOR :
Spring return type, high duty Pneumatic Diaphragm
Actuator.
Diaphragm Cover
Sheet metal pressing.
Diaphragm
Nylon inserted Neoprene
Bottom Cover
High duty cast iron.
Yoke
ASTM. A216 WCB Investment
casted
Actuator Spring
IS 4454 Grade III, duly painted.
Actuator Working
2 to 3.5 bar
Operating Cycles per hour
15mm, 20mm, 25mm upto 800
cy/hr. 35 mm and 50mm upto 300
cy/hr (tested on air, on other
fluids, this figure may vary).
Life Expectancy
Over one million cycles (lab tested in ideal condition).
Air Quality
Dry air or non corrosive gas.
Accessory
Air lock, Solenoid Valve, Filter
Regulator Gauge. Other
accessories available on
application.
Application
For control of air, water, oil, gas,
steam, hydraulic oil.
specially where heavy duty
operations are called for,
specially on tyre and tube
building presses, power
generation, atomic energy,
chemical & petrochemical plant,
PSA nitrogen system, air and
gas dryers, gas generators and
others.
Back Pressure
Refer to AVCON.
Instruction Manual
Refer to 1M 7416B.
SPECIFICATION TABLE
Catalogue
Number
Size
BSP(F)
Orifice
Size
Flow Factor
Kv
Maximum Working Pressure
Safe Working
Pressure
Actuator
Type
Air
Consumption
Air/Gas
Hot Water
Steam
Inch
mm
mm
M³ /hr.
Bar
Bar
Bar
bar
Litres/cy
7416B15
½
15
13
2.8
21
16
16
42
450A
0.150
7416B20
3/4
20
15
4.3
21
16
16
42
550A
0176
7416B25
1
25
19
7.0
21
16
16
42
550C
0.471
7416B35
1 ½
35
34
22.7
21
16
16
42
550D
0.966
7416B50
2
50
45
36.0
21
16
16
42
550D
0.966
OPERATION :
Valve Type 7416B -Normally ‘A’ port is closed
and ‘B’ port is connected to ‘AB’ or ‘AB’ port is
connected to ‘B’.On receiving signal ‘B’ port is
closed and ‘A’ port is connected to ‘A’ or ‘AB’
port is connected to ‘A’. Mixing :
Valves can be used for introducing two different
fluids (mixing) through two different ports to
common port ‘AB’. Diverting :
One fluid coming through port ‘AB’ can be
diverted to ‘A’ port or ‘B’ port.
DIMENSIONS ( IN MM )
Catalogue
Number
Size
A
B
C
ØD
Weight Kgs
Inch
mm
7416B15
½
15
85
50
166
165
2.750
7416B20
3/4
20
110
66
200
184
6.350
7416B25
1
25
120
72
250
241
10.750
7416B35
1 ½
35
150
91
310
300
18.000
7416B50
2
50
190
100
432
300
24.500
•OPEN TOLERANCE ± 3MM ALL OVER.
FLOW DIAGRAMS
Note:
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON.