Home

About Us

Products Newsletter Offshore Capabilities Downloads Contact Us
    Products l Back  
   

2/2- Way Pilot Operated, Diaphragm Type, Solenoid Valves.
for steam and hot water application upto 4 bar pressure,
Normally Closed, Energised To Open

DATA SHEET
9130 D
   
SPECIFICATIONS :
Sizes 10 mm (3/8") to 50 mm (2").
End Connections Standard-BSP.
Construction-Body Upto 20mm (3/4") Brass forged IS 6912 and above in
SS ASTM A351 Gr. CF8 or CF8M.
Diaphragm-Seat Standard EPDM.
Differential Pressure From 0.5 to 4 bar (See table).
Coil Voltage Standard-230-volts, 50Hz AC.
Optional-Any Standard AC range.
Coil Insulation and Temperature Ambient upto 42°C.
Class 'H' insulated upto 155°C.
Class 'C' insulated upto 180°C.
Coil rating
Continuously rated.
Enclosure Standard-General Purpose SQ. moulded coil upto IP-20,
Optional- Weatherproof SQ. moulded coil upto IP-67,
Flameproof Round coil upto FLP IIB/ FLP IIC.
Approvals CMRI Dhanbad.
Fluids Steam temp. upto 150°C.
Hot water temp. upto 95°C.
Sales Point Diaphragm pilot operated, standard valve for low pressure steam application.
Application Steaming equipment, textile, processing equipment, laundry equipment, kitchen equipment and others.
Note Not suitable for back pressure from out let side.
Hot water temperature limited upto 95°C only.
Suitable for wet steam:
Not available in Normally Open Design.
Not available in DC Construction.
For high pressure steam, use valve type 9130H.
For instruction manual refer Gen IMSV & Gen
IM coils.
Manual override not available.
USE OF FILTER IN THE INLET SIDE IS HIGHLY RECOMMENDED.
 

SPECIFICATION TABLE

2/2 WAY NORMALLY CLOSED

Catalogue
Number
pipe
Size
Orifice
Size
Flow Factor
Kv
Minimum
pressure
Maximum Operating Pressure
(bar)
BTP Material Constr.
Ref.
VA
Rating
Coil
Housing
Inch mm M³/hr. bar Hot Water*     Steam     bar Body Seat AC Type
9130D104 3/8 16 2.6 0.5 5 4 40 BR EPDM 159 36 M50-HT SQ
9130D154 1/2 16 3.6 0.5 5 4 40 BR EPDM 159 36 M50-HT SQ
9130D204 3/4 20 5.3 0.5 5 4 40 BR EPDM 159 36 M50-HT SQ
9130D254 1 25 8.6 0.5 5 4 40 CF8 EPDM 159 36 M50-HT SQ
9130D304

1 ¼

28 14.0 0.5 5 4 40 CF8 EPDM 159 36 M50-HT SQ
9130D354

1 ½

34 17.3 0.5 5 4 40 CF8 EPDM 159 36 M50-HT SQ
9130D504 2 45 30.5 0.5 5 4 40 CF8 EPDM 159 36 M50-HT SQ
* Hot water at 95°C only.
 
ELECTRICAL REFERENCE
Coil Type Power Consumption & Watt Rating Class Of
Insulation
Protection
AC
VA Inrush VA Holding
 M 50 HT SQ 50 36 H C  GP/WP IP-67
 M 50 HT RD 50 36 H C  GP/WP IP-67
 M 50 HT  FLP IIB/FLP IIC 50 36 H C  IS 2148 Group IIA, IIB, IIC
 IS 13947 Part I IP-67
 IS 4012 Dustproof/ IS 4013 Dustlight
 
1
 
DIMENSIONS ( IN MM )
Catalogue
Number
Pipe
Size
Constr.
Ref.
A B C D Weight
(Approx.)
Inch kgs.*
9130D104 3/8 159 65 28 129 54 1.110
9130D154 1/2 159 65 28 129 54 1.110
9130D204 3/4 159 80 32 134 66 1.555
9130D254 1 159 95 41 139 77 2.090
9130D304 1 ¼ 159 100 43 144 82 2.435
9130D354 1 ½ 159 118 43 144 97 2.575
9130D504 2 159 137 58 151 117 3.655
* Weight with SQ enclosure only, ask AVCON for other weights.



Valve fitted with M50 RD GP coil-
General purpose enclosure as per IP-20



Valve fitted with M50 RD coil-
Waterproof metallic enclosure as per IS 13947 Part I IP-67



Valve fitted with M50 FLP IIB / FLP IIC coil-
Flameproof metallic enclosure as per IS 2148
Catalogue
Number
Pipe
Size
Constr.
Ref.
E (RADIALLY) F G (APPROX.)
Inch RD GP RD WP    FLP    RD GP RD WP     FLP   RD GP RD WP    FLP  
9130D104 3/8 159 66 96 96 57 68 80 120 125 190
9130D154 1/2 159 66 96 96 57 68 80 120 125 190
9130D204

3/4

159 66 96 96 57 68 80 125 130 195
9130D254 1 159 66 96 96 57 68 80 130 135 200
9130D304 1 ¼ 159 66 96 96 57 68 80 135 140 205
9130D354 1 ½ 159 66 96 96 57 68 80 135 140 205
9130D504 2 159 66 96 96 57 68 80 142 147 212
TEMPERATURE TABLE FOR SATURATED STEAM UNDER GAUGE PRESSURE
Pressure (bar) Temp (°C) Pressure (bar) Temp (°C)
0.5 111 6 165
1 120 7 170
1.5 127 8 175
2 134 9 180
2.5 139 10 184
3 144 11 188
3.5 148 12 191
4 152 13 195
4.5 155 14 198
5 159 15 200
 
FLOW CALCULATION GRAPHS FOR SATURATED STEAM :
The valve flow coefficient Kv = 1, if 1 cubic meter (m³) water (at 30°C) is passing through the valve per hour with a pressure drop (∆P) of 1 bar. To select the right valve with certain Kv value, read the steam flow graphs as follows.
EXAMPLE :
A valve is required to pass 400 Kg/h (Qm) of saturated steam at inlet pressure of 7 bar (g) ∆P of 0.5 bar : What is the Kv?  
SOLUTION :
Read the steam graph to find the graph factor (Fg) and use the formula : Kv=QM/Fg = 400/45 = 8.5
NOTE :
Absolute pressure = gauge pressure plus atmospheric pressure of 1.033 bar. In most system it is desirable to keep the pressure drop to a minimum. Never use a  ∆P greater than 50% of the absolute inlet pressure because excessive pressure drop cause irregular flow.
 
 
Note:
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON.
   