Home > Solenoid Valves > 2 Way Solenoid Valves for Steam & Hot Water > 9130H  
  2/2-Way Pilot Operated, Piston Type, Solenoid Valves
For steam and hot water application, upto 9 bar pressure, Normally Closed, Energised To Open
DATA SHEET
9130 H
   
SPECIFICATIONS :
Sizes 10 mm (3/8") to 50 mm (2").
End Connections Standard-BSP.
Construction -Body Upto 20mm (3/4") Brass forged IS 6912 and above in
SS ASTM A351 Gr. CF8.
                         -Seat Standard-PTFE.
Optional-PTFE backed by EPDM.
Differential Pressure From 1.4 to 9 bar (See table).
Coil Voltage Standard-230-volts, 50Hz AC.
Optional-Any Standard AC voltage range.
Coil Insulation and Temperature Ambient upto 42°C.
Class 'H' insulated upto 155°C.
Class 'C' insulated upto 180° C.
Coil rating
Continuously rated.
Enclosure Standard-General Purpose SQ. moulded coil upto IP-20,
Optional- Weatherproof SQ. moulded coil upto IP-67,
Flameproof Round coil upto FLP IIB/ FLP IIC.
Approvals CIMFR Dhanbad.
Fluids Steam temp. upto 180°C.
Hot water temp. upto 95°C.
Sales Point Pilot operated, standard valve for high pressure steam application.
Application Steaming equipment, textile, processing equipment, laundry equipment, kitchen equipment and others.
Note Not suitable for back pressure working from outlet side.
Hot water temperature limited upto 95°C only.
Not suitable for wet steam:
Not available in Normally Open design.
Manual override not available.
Not available in DC.
For application where the steam pressure is below 4 bar, we recommend use of 9130D design valves, with EPDM diaphragm
(Refer to data sheet 9130D).
USE OF FILTER IN THE INLET SIDE IS HIGHLY RECOMMENDED.

SPECIFICATION TABLE

2/2 WAY NORMALLY CLOSED

Catalogue
Number
pipe
Size
Orifice
Size
Flow Factor
Kv
Minimum
pressure
Maximum Operating Pressure
(bar)
BTP Material Constr.
Ref.
VA
Rating
Coil Housing
Inch mm M³/hr. bar Hot Water*     Steam     bar Body Seat AC Type
9130H104 3/8 16 2.6 1.4 9 9 40 BR PTFE 160 36 M50-HT SQ
9130H154 1/2 16 3.6 1.4 9 9 40 BR PTFE 160 36 M50-HT SQ
9130H204 3/4 20 5.3 1.4 9 9 40 BR PTFE 160 36 M50-HT SQ
9130H254 1 25 8.6 1.4 9 9 40 CF8 PTFE 160 36 M50-HT SQ
9130H304 28 14.0 1.4 9 9 40 CF8 PTFE 160 36 M50-HT SQ
9130H354 34 17.3 1.4 9 9 40 CF8 PTFE 160 36 M50-HT SQ
9130H504 2 45 30.5 1.4 9 9 40 CF8 PTFE 160 36 M50-HT SQ
* Hot water at 95°C only.
 
ELECTRICAL REFERENCE
Coil Type Power Consumption & Watt Rating Class Of
Insulation
Protection
AC
VA Inrush VA Holding
 M 50 HT SQ 50 36 H C  GP/WP IP-67
 M 50 HT RD 50 36 H C  GP/WP IP-67
 M 50 HT
 FLP IIB/FLP IIC
50 36 H C  IS 2148 Group IIA, IIB, IIC
 IS 13947 Part I IP-67
 IS 4012 Dustproof/ IS 4013 Dustlight
 
1
 
DIMENSIONS ( IN MM )
Catalogue
Number
Pipe
Size
Constr.
Ref.
A B C D Weight
(Approx.)
Inch kgs.*
9130H104 3/8 160 65 28 129 68 1.375
9130H154 1/2 160 65 28 129 68 1.375
9130H204 3/4 160 80 32 134 79 1.805
9130H254 1 160 95 41 139 93 2.295
9130H304 1 ¼ 160 100 43 144 106 2.575
9130H354 1 ½ 160 118 43 144 117 3.080
9130H504 2 160 137 58 151 135 4.495
 
CONSTRUCTION REF.NO.: 160



TEMPERATURE TABLE FOR SATURATED STEAM UNDER GAUGE PRESSURE
Pressure (bar) Temp (°C) Pressure (bar) Temp (°C)
0.5 111 6 165
1 120 7 170
1.5 127 8 175
2 134 9 180
2.5 139 10 184
3 144 11 188
3 148 12 191
4 152 13 195
4.5 155 14 198
5 159 15 200
Valve fitted with M50 RD GP coil-
General purpose enclosure as per IP-20


Valve fitted with M50 RD coil-
Waterproof metallic enclosure as per IS 13947 Part I IP-67


Valve fitted with M50 FLP IIB / FLP IIC coil-
Flameproof metallic enclosure as perIS/IEC-60079-1-2007
 
Catalogue
Number
Pipe
Size
Constr.
Ref.
E (RADIALLY) F G (APPROX.)
Inch RD GP RD WP    FLP    RD GP RD WP     FLP   RD GP RD WP    FLP  
9130H104 3/8 160 66 96 96 57 68 80 120 125 190
9130H154 1/2 160 66 96 96 57 68 80 120 125 190
9130H204 3/4 160 66 96 96 57 68 80 125 130 195
9130H254 1 160 66 96 96 57 68 80 130 135 200
9130H304 1 ¼ 160 66 96 96 57 68 80 135 140 205
9130H354 1 ½ 160 66 96 96 57 68 80 135 140 205
9130H504 2 160 66 96 96 57 68 80 142 147 212
 
 
FLOW CALCULATION GRAPHS FOR SATURATED STEAM :
The valve flow coefficient Kv = 1, if 1 cubic meter (m³) water (at 30°C) is passing through the valve per hour with a pressure drop (∆P) of a bar. To select the right valve with certain Kv value, read to steam flow graphs as follows.
 
EXAMPLE :
A valve is required to pass 400 Kg/h (Qm) of saturated steam at inlet pressure of 7 bar (g) ∆P of 0.5 bar : What is the Kv?
 
SOLUTION :
Read the steam graph to find the graph factor (Fg) and use the formula : Kv=QM/Fg = 400/45 = 8.5
 
NOTE :
Absolute pressure = gauge pressure plus atmospheric pressure of 1.033 bar. In most system it is desirable to keep the pressure drop to a minimum. Never use a  ∆P greater than 50% of the absolute inlet pressure because excessive pressure drop cause irregular flow.
 
* Weight with SQ enclosure only, ask AVCON for other weights.
 
Note:
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON.
   
 
Home > Solenoid Valves > 2 Way Solenoid Valves for Steam & Hot Water > 9130H
 
 
 
   
About Us | Industries We Serve | Distribution Network | Quality | Downloads | Contact Us
Copyright Avcon Controls Pvt. Ltd, 2011-2012. All Rights Reserved.