  2/2-Way Pilot Operated, Diaphragm Type Solenoid Valves
For air,water and hot water application upto 10 bar pressure,
Normally Closed, Energised To Open
Normally Open, Energised To Close
DATA SHEET
9131 R
9132 R
   
SPECIFICATIONS :
Sizes 10mm (3/8”) to 25mm (1”).
End Connections Standard-BSP('G' Threads).
Construction-Body Upto 25mm ('1') Brass forged, IS 6912,Optional-SS ASTM A 351 Gr.CF8 or CF8M.
Diaphragm Standard-EPDM,
Optional-Viton/BN.
Pilot-Seat Standard-Epdm,
Optional-Viton/BN.
Differential Pressure From 0.5 to 10 bar (see table).
Coil Voltage Standard-230-Volts, 50Hz. AC.
Optional-Any Standard AC Voltage range.
Coil Insulation and Temperature Ambient upto 42° C. Class 'C' insulated upto 180° C.
Coil Rating Continuously rated.
Enclosure Standard-General purpose SQ. moulded coil upto IP-20, Optional-Wheatherproof SQ. moulded coil up to ip-67,Flameproof Round coil upto FLP IIB/FLP IIC.
Approvals CIMFR Dhanbad, CCE.
Fluids Hot water temp.upto 95° C .
 
Note Not suitable for back pressure from outlet side. Hot water temperature limited upto 95° C only. Available in Normally Open design.
Not available in DC construction. For instruction manual refer ISMV & General IM Coils.
USE OF FILTER IN THE INLET SIDE IS HIGHLY RECOMMENDED.

SPECIFICATION TABLE

2/2 WAY NORMALLY CLOSED

Catalogue
Number
pipe
Size
Orifice
Size
Flow Factor
Kv
Minimum
pressure
Maximum Operating Pressure
(bar)
BTP Material Constr.
Ref.
VA
Rating
Coil Housing
Inch mm M³/hr. bar Air Water Hot Water bar Body Seat AC Type
9131R10 3/8 10 1.4 0.5 10 10 9 40  BR  EPDM
107 18 M45.1 SQ
9131R15 1/2 10 1.5 0.5 10 10 9 40 BR EPDM 107 18 M45.1 SQ
9131R20 3/4 18 2.25 0.5 10 10 9 40 BR EPDM 107 18 M45.1 SQ
9131R25 1 18 2.6 0.5 10 10 9 40 BR EPDM 107 18 M45.1 SQ
 
2/2 WAY NORMALLY OPEN
9132R10 3/8 10 1.4 0.5 10 10 9 40  BR  EPDM
107 18 M45.1 SQ
9132R15 1/2 10  1.5 0.5 10 10 9 40 BR EPDM 107 18 M45.1 SQ
9132R20 3/4 18 2.25 0.5 10 10 9 40 BR EPDM 107 18 M45.1 SQ
9132R25 1 18 2.25 0.5 10 10 9 40 BR EPDM 107 18 M45.1 SQ
*Hot water at 90° C only. Coil will be M45-HT. For steam duty use 9131EXX valves.
 
ELECTRICAL REFERENCE
Coil Type Power Consumption
& Watt Rating
Class
of
Insulation
Protection
AC
VA Inrush VA Holding
M 45.1 SQ 25 18 H C GP/WP IP-67
M 45.1 RD 25 18 H C GP/WP IP-67
M 45.1
FLP IIB / FLP IIC
25 18 H C IS 2148-2004 Group IIA, IIB,IIC
IS 12063-1987 IP-67
IS 4012-1967Dustproof/IS 4013-1967 Dusttight
 
1
 
DIMENSIONS (IN MM)
Catalogue
Number
Pipe
Size
Constr.
Ref.
A B C D Weight
(APPROX.)
Normally
Closed
Normally
Open
Inch KGS*
9131R10 9132R10 3/8 107 48 15 91 48.5 0.723
9131R15 9132R10 1/2 107 48 15 91 48.5 0.673
9131R20 9132R10 3/4 107 65 16.5 99 51 0.903
9131R25 9132R10 1 107 68 18.5 99 51 0.953
Valve fitted with M45 RD GP coil-
General purpose enclosure as per IP-20


Valve fitted with M45 RD coil-
Waterproof metallic enclosure as per IS 12063 Part I IP-67


Valve fitted with M45 FLP IIB/FLP IIC coil-
Flameproof metallic enclosure as perIS/IEC-60079-1-2007-2004
CONSTRUCTION REF. NO. : 107
Catalogue Number Pipe
Size
Constr.
Ref.
E(Radially) F G (APPROX.)
Normally
Closed
Normally
Open
Inch RD WP RD WP FLP RD GD RD WP FLP RD GD RD WP FLP
9131R10 9132R10 3/8 107 60 96 96 48 62 80 78 86 156
9131R15 9132R15 1/2 107 60 96 96 48 62 80 78 86 156
9131R20 9132R20 3/4 107 60 96 96 48 62 80 86 94 164
9131R25 9132R25 1 107 60 96 96 48 62 80 86 94 164
 
TABLE FOR SATURATED STEAM
UNDER ABSOLUTE PRESSURE
Outlet Pres.
bar(abs)
Temp.
(° C )
Sp. Volume
M³/Kg
0.5 80.9 3.30
1.0 99.1 1.73
1.5 110.8 1.18
2.0 119.6 0.90
2.5 126.8 0.73
3.0 132.9 0.62
3.5 138.2 0.53
4.0 142.9 0.47
4.5 147.2 0.42
5.0 151.1 0.38
5.5 154.7 0.35
6.0 158.1 0.32
6.5 161.2 0.30
7.0 164.2 0.28
7.5 167.0 0.26
 
Outlet Press
bar(abs)
Temp.
(° C )
Sp. Volume
M³/Kg
8.0 169.6 0.25
8.5 172.1 0.23
9.0 174.5 0.22
9.5 176.8 0.21
10.0 179.0 0.20
11.0 183.2 0.181
12.0 187.1 0.176
13.0 190.7 0.155
14.0 194.1 0.144
15.0 197.4 0.135
16.0 200.4 0.126
17.0 203.4 0.119
18.0 206.2 0.113
19.0 208.8 0.107
20.0 211.4 0.102
 
APPROVAL AND CERTIFICATIONS
CIMFR For Flame/ Explosion proof
Enclosure for Group IIB & IIC.
CCE NAGPUR For Flame/ Explosion proof
Enclosure for Group IIB
BIS LICENCE For ISI Mark-Flame/Explosion proof
Enclosure for Group IIB
GOST CERTIFICATE Basic Eligibility as on Exporter to
Russia.
GOSGORTECHNADZOR
CERTIFICATE
Product approval Hazardous
Areas-Russia.
HYGIENIC CERTIFICATE Approval to supply products for use
in food and Beverages industries
 
INSTALLATION
1) Use good quality pipe line strainer before solenoid valve; USE of NON RETURN VALVE after valve is recommended.
2) Valve can be mounted in any position, but keeping solenoid upright and vertical.
3) Not advisable for DC voltage.
 
* Weight with SQ enclosure only, ask AVCON for other weights.
 
Note:
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON.
   
 
Home > Solenoid Valves > 2 Way Solenoid Valves for Steam & Hot Water > 9131R
 
 
 
   
About Us | Industries We Serve | Distribution Network | Quality | Downloads | Contact Us
Copyright Avcon Controls Pvt. Ltd, 2011-2012. All Rights Reserved.