Home > Solenoid Valves > 2 Way Solenoid Valves for Steam & Hot Water > 9131R |
|
| |
2/2-Way Pilot Operated, Diaphragm Type Solenoid Valves
For air,water and hot water application upto 10 bar pressure,
Normally Closed, Energised To Open
Normally Open, Energised To Close |
DATA SHEET
9131 R
9132 R |
|
| |
|
| SPECIFICATIONS : |
| Sizes |
10mm (3/8”) to 25mm (1”). |
| End Connections |
Standard-BSP('G' Threads). |
| Construction-Body |
Upto 25mm ('1') Brass forged, IS 6912,Optional-SS ASTM A 351 Gr.CF8 or CF8M. |
| Diaphragm |
Standard-EPDM,
Optional-Viton/BN. |
| Pilot-Seat |
Standard-Epdm,
Optional-Viton/BN. |
| Differential Pressure |
From 0.5 to 10 bar (see table). |
| Coil Voltage |
Standard-230-Volts, 50Hz. AC.
Optional-Any Standard AC Voltage range. |
| Coil Insulation and Temperature |
Ambient upto 42° C. Class 'C' insulated upto 180° C. |
| Coil Rating |
Continuously rated. |
| Enclosure |
Standard-General purpose SQ. moulded coil upto IP-20, Optional-Wheatherproof SQ. moulded coil up to ip-67,Flameproof Round coil upto FLP IIB/FLP IIC. |
| Approvals |
CIMFR Dhanbad, CCE. |
| Fluids |
Hot water temp.upto 95° C . |
|
 |
| |
| Note |
Not suitable for back pressure from outlet side. Hot water temperature limited upto 95° C only. Available in Normally Open design.
Not available in DC construction. For instruction manual refer ISMV & General IM Coils.
USE OF FILTER IN THE INLET SIDE IS HIGHLY RECOMMENDED. |
|
|
|
 |
SPECIFICATION TABLE
2/2 WAY NORMALLY CLOSED |
Catalogue
Number |
pipe
Size |
Orifice
Size |
Flow Factor
Kv |
Minimum
pressure |
Maximum Operating Pressure
(bar) |
BTP |
Material |
Constr.
Ref. |
VA
Rating |
Coil |
Housing |
| Inch |
mm |
M³/hr. |
bar |
Air |
Water |
Hot Water |
bar |
Body |
Seat |
AC |
Type |
| 9131R10 |
3/8 |
10 |
1.4 |
0.5 |
10 |
10 |
9 |
40 |
BR |
EPDM |
107 |
18 |
M45.1 |
SQ |
| 9131R15 |
1/2 |
10 |
1.5 |
0.5 |
10 |
10 |
9 |
40 |
BR |
EPDM |
107 |
18 |
M45.1 |
SQ |
| 9131R20 |
3/4 |
18 |
2.25 |
0.5 |
10 |
10 |
9 |
40 |
BR |
EPDM |
107 |
18 |
M45.1 |
SQ |
| 9131R25 |
1 |
18 |
2.6 |
0.5 |
10 |
10 |
9 |
40 |
BR |
EPDM |
107 |
18 |
M45.1 |
SQ |
|
| |
| 2/2 WAY NORMALLY OPEN |
 |
| 9132R10 |
3/8 |
10 |
1.4 |
0.5 |
10 |
10 |
9 |
40 |
BR |
EPDM |
107 |
18 |
M45.1 |
SQ |
| 9132R15 |
1/2 |
10 |
1.5 |
0.5 |
10 |
10 |
9 |
40 |
BR |
EPDM |
107 |
18 |
M45.1 |
SQ |
| 9132R20 |
3/4 |
18 |
2.25 |
0.5 |
10 |
10 |
9 |
40 |
BR |
EPDM |
107 |
18 |
M45.1 |
SQ |
| 9132R25 |
1 |
18 |
2.25 |
0.5 |
10 |
10 |
9 |
40 |
BR |
EPDM |
107 |
18 |
M45.1 |
SQ |
|
| *Hot water at 90° C only. Coil will be M45-HT. For steam duty use 9131EXX valves. |
| |
| ELECTRICAL REFERENCE |
| Coil Type |
Power Consumption
& Watt Rating |
Class
of
Insulation |
Protection |
| AC |
| VA Inrush |
VA Holding |
| M 45.1 SQ |
25 |
18 |
H |
C |
GP/WP IP-67 |
| M 45.1 RD |
25 |
18 |
H |
C |
GP/WP IP-67 |
M 45.1
FLP IIB / FLP IIC |
25 |
18 |
H |
C |
IS 2148-2004 Group IIA, IIB,IIC
IS 12063-1987 IP-67
IS 4012-1967Dustproof/IS 4013-1967 Dusttight |
|
|
| DIMENSIONS (IN MM) |
Catalogue
Number |
Pipe
Size |
Constr.
Ref. |
A |
B |
C |
D |
Weight
(APPROX.) |
Normally
Closed |
Normally
Open |
Inch |
KGS* |
| 9131R10 |
9132R10 |
3/8 |
107 |
48 |
15 |
91 |
48.5 |
0.723 |
| 9131R15 |
9132R10 |
1/2 |
107 |
48 |
15 |
91 |
48.5 |
0.673 |
| 9131R20 |
9132R10 |
3/4 |
107 |
65 |
16.5 |
99 |
51 |
0.903 |
| 9131R25 |
9132R10 |
1 |
107 |
68 |
18.5 |
99 |
51 |
0.953 |
|
 |
Valve fitted with M45 RD GP coil-
General purpose enclosure as per IP-20
Valve fitted with M45 RD coil-
Waterproof metallic enclosure as per IS 12063 Part I IP-67
Valve fitted with M45 FLP IIB/FLP IIC coil-
Flameproof metallic enclosure as perIS/IEC-60079-1-2007-2004
 |
CONSTRUCTION REF. NO. : 107
 |
|
| Catalogue Number |
Pipe
Size |
Constr.
Ref. |
E(Radially) |
F |
G (APPROX.) |
Normally
Closed |
Normally
Open
|
Inch |
RD WP |
RD WP |
FLP |
RD GD |
RD WP |
FLP |
RD GD |
RD WP |
FLP |
| 9131R10 |
9132R10 |
3/8 |
107 |
60 |
96 |
96 |
48 |
62 |
80 |
78 |
86 |
156 |
| 9131R15 |
9132R15 |
1/2 |
107 |
60 |
96 |
96 |
48 |
62 |
80 |
78 |
86 |
156 |
| 9131R20 |
9132R20 |
3/4 |
107 |
60 |
96 |
96 |
48 |
62 |
80 |
86 |
94 |
164 |
| 9131R25 |
9132R25 |
1 |
107 |
60 |
96 |
96 |
48 |
62 |
80 |
86 |
94 |
164 |
|
| |
TABLE FOR SATURATED STEAM
UNDER ABSOLUTE PRESSURE |
Outlet Pres.
bar(abs) |
Temp.
(° C ) |
Sp. Volume
M³/Kg |
| 0.5 |
80.9 |
3.30 |
| 1.0 |
99.1 |
1.73 |
| 1.5 |
110.8 |
1.18 |
| 2.0 |
119.6 |
0.90 |
| 2.5 |
126.8 |
0.73 |
| 3.0 |
132.9 |
0.62 |
| 3.5 |
138.2 |
0.53 |
| 4.0 |
142.9 |
0.47 |
| 4.5 |
147.2 |
0.42 |
| 5.0 |
151.1 |
0.38 |
| 5.5 |
154.7 |
0.35 |
| 6.0 |
158.1 |
0.32 |
| 6.5 |
161.2 |
0.30 |
| 7.0 |
164.2 |
0.28 |
| 7.5 |
167.0 |
0.26 |
|
|
Outlet Press
bar(abs) |
Temp.
(° C ) |
Sp. Volume
M³/Kg |
| 8.0 |
169.6 |
0.25 |
| 8.5 |
172.1 |
0.23 |
| 9.0 |
174.5 |
0.22 |
| 9.5 |
176.8 |
0.21 |
| 10.0 |
179.0 |
0.20 |
| 11.0 |
183.2 |
0.181 |
| 12.0 |
187.1 |
0.176 |
| 13.0 |
190.7 |
0.155 |
| 14.0 |
194.1 |
0.144 |
| 15.0 |
197.4 |
0.135 |
| 16.0 |
200.4 |
0.126 |
| 17.0 |
203.4 |
0.119 |
| 18.0 |
206.2 |
0.113 |
| 19.0 |
208.8 |
0.107 |
| 20.0 |
211.4 |
0.102 |
|
|
| APPROVAL AND CERTIFICATIONS |
| CIMFR |
For Flame/ Explosion proof
Enclosure for Group IIB & IIC. |
| CCE NAGPUR |
For Flame/ Explosion proof
Enclosure for Group IIB |
| BIS LICENCE |
For ISI Mark-Flame/Explosion proof
Enclosure for Group IIB |
| GOST CERTIFICATE |
Basic Eligibility as on Exporter to
Russia. |
GOSGORTECHNADZOR
CERTIFICATE |
Product approval Hazardous
Areas-Russia. |
| HYGIENIC CERTIFICATE |
Approval to supply products for use
in food and Beverages industries |
| |
| INSTALLATION |
1) Use good quality pipe line strainer before solenoid valve; USE of NON RETURN VALVE after valve is recommended.
2) Valve can be mounted in any position, but keeping solenoid upright and vertical.
3) Not advisable for DC voltage. |
|
|
|
|
| |
| * Weight with SQ enclosure only, ask AVCON for other weights. |
| |
| Note: |
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON. |
| |
|
|
|
|