Flanged valve body in Cast Iron material, reliable & build around modular concept.
Application
Textile processing machinery, sugar machinery, silo fluidisation or wherever dependable on-off type control is required.
Not suitable
for steam duty.
Note
USE OF FILTER IN THE INLET SIDE IS HIGHLY RECOMMENDED.
SPECIFICATION TABLE
2/2 WAY NORMALLY CLOSED
Catalogue
Number
pipe
Size
Orifice
Size
Flow
Factor
Kv
Minimum
pressure
Maximum Operating Pressure
(bar)
BTP
Material
Constr.
Ref.
VA
Rating
Watt
Rating
Coil
Housing
AC
DC
Inch
mm
M³/hr
bar
Air/Gas
Water
Light Oil
Air/Gas
Water
Light Oil
bar
Body
Seat
AC
DC
Type
9160K25
1
25
11
0.6
6
6
5
6
6
5
26
CI
BN
32.1
18
12
M45.1
SQ
9160K35
1 ½
35
23
0.6
6
6
5
6
6
5
26
CI
BN
32.1
18
12
M45.1
SQ
9160K50
2
50
39
0.6
6
6
4
6
6
4
26
CI
BN
32.1
18
12
M45.1
SQ
9160K65
2 ½
63
46
0.6
5
5
4
5
5
4
26
CI
BN
161
36
22
M50
SQ
9160K75
3
76
64
0.6
5
5
4
4
4
3
26
CI
BN
161
36
22
M50
SQ
9160K100
4
94
101
0.6
4
4
3
3
3
2
26
CI
BN
161
36
22
M50
SQ
9160K150
6
146
230
0.6
3
3
2
3
3
2
26
CI
BN
161
36
22
M50
SQ
2/2 WAY NORMALLY OPEN
9162K25
1
25
11
0.6
6
6
4
5
5
4
26
CI
BN
32.1
18
12
M45.1
SQ
9162K35
1 ½
35
23
0.6
6
6
4
4
4
3
26
CI
BN
32.1
18
12
M45.1
SQ
9162K50
2
50
39
0.6
6
5
4
4
4
3
26
CI
BN
32.1
18
12
M45.1
SQ
9162K65
2 ½
63
46
0.6
5
4
4
4
4
3
26
CI
BN
161
36
22
M50
SQ
9162K75
3
76
64
0.6
4
4
3
3
3
2
26
CI
BN
161
36
22
M50
SQ
9162K100
4
94
101
0.6
3
3
2
2
2
2
26
CI
BN
161
36
22
M50
SQ
ELECTRICAL REFERENCE
Coil Type
Power Consumption & Watt Rating
Class Of
Insulation
Protection
A.C.
D.C.
VA
Inrush
VA
Holding
Watts
M 45.1 SQ
25
18
12
H
C
GP/WP IP-67
M 50 SQ
50
36
22
H
C
GP/WP IP-67
M 45.1 RD
25
18
12
H
C
GP/WP IP-67
M 50 RD
50
36
22
H
C
GP/WP IP-67
M 45.1 FLP IIB/ FLP IIC
25
18
12
H
C
IS 2148 Group IIA, IIB, IIC
IS 13947 Part I IP 67
IS 4012 Dustproof / IS 4013 Dusttight
M 50 FLP IIB/ FLP IIC
50
36
22
H
C
DIMENSIONS ( IN MM )
Catalogue
Number
Pipe
Size
Constr.
Ref.
A
DIN
3202
B
C
ØD
Weight
(Approx.)
Normally
Closed
Normally
Open
Inch
Kgs*
9160K25
9162K25
1
32.1
160
54
148
105
5.023
9160K35
9162K35
1 ½
32.1
200
64
166
135
8.323
9160K50
9162K50
2
32.1
230
76
173
160
11.223
9160K65
9162K65
2 ½
161
290
89
198
180
15.378
9160K75
9162K75
3
161
310
96
192
200
18.684
9160K100
9162K100
4
161
350
115
228
225
21.684
9160K150
---
6
161
480
140
268
316
32.925
CONSTRUCTION REF.NO.: 32.1
CONSTRUCTION REF.NO.: 161
Valve fitted with M45 / M50 RD GP coil-
General purpose enclosure as per IP-20
Valve fitted with M45 / M50 RD coil-
Waterproof metallic enclosure as per IS 13947 Part I IP-67
Valve fitted with M45 / M50 FLP IIB / FLP IIC coil-
Flameproof metallic enclosure as per IS 2148
Catalogue Number
Pipe Size
Constr.
Ref.
E (RADIALLY)
F
G (APPROX.)
Normally
Closed
Normally
Open
Inch
RD GP
RD WP
FLP
RD GP
RD WP
FLP
RD GP
RD WP
FLP
9160K25
9162K25
1
32.1
60
96
96
48
62
80
135
143
213
9160K35
9162K35
1 ½
32.1
60
96
96
48
62
80
153
161
231
9160K50
9162K50
2
32.1
60
96
96
48
62
80
160
168
238
9160K65
9162K65
2 ½
161
66
96
96
57
68
80
189
194
259
9160K75
9162K75
3
161
66
96
96
57
68
80
183
188
253
9160K100
9162K100
4
161
66
96
96
57
68
80
219
224
289
9160K150
---
6
161
66
96
96
57
68
80
259
264
329
* Weight with SQ enclosure only, ask AVCON for other weights.