Home

About Us

Products Newsletter Offshore Capabilities Downloads Contact Us
    Products l Back  
   

3/2- Way Direct Acting, Solenoid Valves.
Normally Closed, Normally Open, Universal Type.

DATA SHEET
9307 F/G/U
   
SPECIFICATIONS :
Sizes 6 mm (1/4") to 15 mm (1/2")
End Connections Standard-BSP.
Optional-NPT
Construction-Body Standard-Brass bar stock.
Optional-Stainless Steel bar stock.
-Seat Standard-Nitrile (Buna-'N')
Optional-Viton, Neoprene, Teflon, EPDM & Silicon.
Differential Pressure 0 to 7 bar.
Temperature of Fluid -5°C to 120°C
Coil Voltage Standard-230-volts, 50Hz A.C.
Optional-Any Standard A.C./D.C. voltage range.
Coil Insulation and Temperature Ambient upto 75 ° C. Class 'F' insulated upto 155°C,
Class 'H' insulated upto 180°C.
Coil rating
Continuously rated.
Enclosure Standard-General Purpose IP-20,
Optional- Weatherproof IP-67,
Flameproof upto FLP II B - II C.
Fluids Air, water, gas, light oil, corrosive fluids.
Optional Features Manual override,mounting bracket.
Sales Point 3-way Direct Acting valve having large port area.
Application For operating Diaphragm valves. Single acting cylinders, clutches, compressor loading and uploading.
Note USE OF FILTER IN THE INLET SIDE IS HIGHLY RECOMMENDED.
 

SPECIFICATION TABLE

3/2 WAY NORMALLY CLOSED  
Catalogue
Number
pipe
Size
(Inch)
Orifice
Size
(mm)
Flow Factor
Kv
M³ /h
Minimum
pressure
bar
Maximum Operating Pressure
(bar)
S.W.P. Material Const.
Ref.
VA
Rating
~
Watt
Rating
=
Coil
Type
Housing
A.C. D.C.
Air/Gas Water Light Oil Air/Gas Water Light Oil bar Body Seat
9307F06 1/4 9 0.68 0 7 6 4 7 6.5 4.5 20 BR BN 163 36 22 M 50 SQ
9307F10 3/8 9 0.68 0 7 6 4 7 6.5 4.5 20 BR BN 163 36 22 M 50 SQ
9307F15 1/2 9 0.68 0 7 6 4 7 6.5 4.5 20 BR BN 163 36 22 M 50 SQ
3/2 WAY NORMALLY OPEN
9307G06 1/4 9 0.68 0 7 6 4 7 6.5 4.5 20 BR BN 163 36 22 M 50 SQ
9307G10 3/8 9 0.68 0 7 6 4 7 6.5 4.5 20 BR BN 163 36 22 M 50 SQ
9307G15 1/2 9 0.68 0 7 6 4 7 6.5 4.5 20 BR BN 163 36 22 M 50 SQ
3/2 WAY UNIVERSAL TYPE
9307U06 1/4 9 0.68 0 5 3.5 3 5 4 3 20 BR BN 163 36 22 M 50 SQ
9307U10 3/8 9 0.68 0 5 3.5 3 5 4 3 20 BR BN 163 36 22 M 50 SQ
9307U15 1/2 9 0.68 0 5 3.5 3 5 4 3 20 BR BN 163 36 22 M 50 SQ
 
1
 
ELECTRICAL REFERENCE
Coil Type Power Consumption & Watt Rating Class Of
Insulation
Protection
A.C. D.C.
VA
Inrush
VA
Holding
Watts
M 50 SQ 50 36 22 H C GP/WP IP-67
M 50 RD 50 36 22 H C GP/WP IP-67
M 50 FLP IIB FLP IIC 50 36 22 H C IS 2148 Group IIA, IIB, IIC
IS 13947 Part l IP-67
IS 4012 Dustproof / IS 4013 Dusttight
 
DIMENSIONS ( IN MM )
 
Catalogue
Number
Pipe
Size
(Inch)
Constr.
Ref.
A B C D Weight
kgs.*
9307F/G/U 1/4 163 50 42 96 57 1.215
9307F/G/U 3/8 163 64 42 96 57 1.57
9307F/G/U 1/2 163 64 42 96 57 1.57
*Wt. is Without manual override and mounting bracket, for MO Add 50 gms. and MB add 200 gms.
Weight with SQ enclosure only, ask AVCON for other weights.
 
CONSTRUCTION REF. NO.: 83.1



Valve fitted with M50 RD GP coil-
General purpose enclosure as per IP-20


Valve fitted with M50 RD coil-
Waterproof metallic enclosure as per IS 13947 Part I IP-67


Valve fitted with M50 FLP IIB / FLP IIC coil-
Flameproof metallic enclosure as per IS 2148
OPTIONAL MOUNTING BRACKET
BRACKET CAN BE ROTATED 360°C
TO FACILITATE MOUNTING
MANUAL OPERATOR
(OPTIONAL) PUSH TYPE
 
Catalogue Number Pipe Size Constr.
Ref.
E (RADIALLY) F G (APPROX.)
Inch RD GP RD WP    FLP     RD GP RD WP    FLP     RD GP RD WP   FLP  
9307F/G/U 1/4 163 66 96 96 57 68 80 87 92 157
9307F/G/U 3/8 163 66 96 96 57 68 80 87 92 157
9307F/G/U 1/2 163 66 96 96 57 68 80 87 92 157
 
Note:
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON.
   
Products l Back
   
  home l about us l products l newsletter l offshore capabilities l downloads l sitemap l faq l contact us Copyright © 2008 All Rights Reserved