4/2 Way Pilot Operated, Poppet
Type, Solenoid Valves.
2 Position Single And Duel Solenoids. |
DATA SHEET
9470 D
9472 D |
|
| |
|
| SPECIFICATIONS : |
| Sizes |
6 mm (1/4") to 15 mm (1/2") |
| End Connections |
Standard-BSP,
Optional-NPT |
| Construction - Body |
Standard - Aluminium deep anodised bar stock.
Optional-Brass/Stainless steel
bar stock (few models) |
| - Seat |
Standard - Nitrile (Buna 'N')
Optional - Viton |
| Differential Pressure |
From 2 to 10 bar. |
| Temperature of fluid |
- 5°C to 80°C. |
| Coil voltage |
Standard -230-volts,
50 Hz A.C.
Optional -Any standard
A.C./ D.C.voltage. |
Coil insulation
and Temperature |
Ambient upto 42 °C.
Class 'H' insulated
upto 155°C,
Class 'C' insulated
upto 180°C. |
| Coil rating |
Continuously rated. |
| Enclosure |
Standard - General
Purpose SQ. moulded coil upto IP - 20,
Optional - Weatherproof SQ. moulded coil
upto IP - 67,
Flameproof Round coil upto FLP IIB / FLP IIC.
(Except 9472 D 06) |
| Fluids |
Lubricated and non-lubricated
air, gas, (with modification-light
oil.) |
| Optional features |
External pilot fluid. |
|
 |
| Sales Point |
Reliable, fast acting valve for
multimillion operations. Lockable
resettable manual override as a
standard. (Except 9472D06). |
| Application |
For operating double acting
cylinders or two single acting
cylinders, used in pneumatic
circuitory, textile processing
machinery, for operation of
quarter turn actuators, robots
and others. |
| Note |
USE OF FILTER IN THE INLET
SIDE IS HIGHLY
RECOMMENDED. |
|
|
|
| |
SPECIFICATION TABLE
|
| 4/2 POSITION SINGLE SOLENOID |
|
 |
|
Catalogue
Number |
pipe
Size
(Inch) |
Orifice
Size
(mm) |
Flow Factor
Kv
M³ /h
|
Minimum
pressure
bar |
Maximum Operating Pressure
(bar) |
S.W.P. |
Material |
Const.
Ref. |
VA
Rating
~ |
Watt
Rating
= |
Coil
Type
|
Housing |
| A.C. |
D.C. |
| Air/Gas |
Water |
Light Oil |
Air/Gas |
Water |
Light Oil |
bar |
Body |
Seat |
| 9470 D 06 |
1/4 |
6 |
0.6 |
2 |
10 |
-- |
-- |
10 |
-- |
-- |
15 |
AL |
BN |
26.1 |
18 |
12 |
M 45.1 |
SQ |
| 9470 D 10 |
3/8 |
10 |
1 |
2 |
10 |
-- |
-- |
10 |
-- |
-- |
15 |
AL |
BN |
26.1 |
18 |
12 |
M 45.1 |
SQ |
| 9470 D 15 |
1/2 |
12 |
1.14 |
2 |
10 |
-- |
-- |
10 |
-- |
-- |
15 |
AL |
BN |
26.1 |
18 |
12 |
M 45.1 |
SQ |
| 4/2 POSITION DUAL SOLENOIDS |
 |
| *9472 D 06 |
1/4 |
6 |
0.7 |
2 |
10 |
-- |
-- |
10 |
-- |
-- |
15 |
AL |
BN |
27.1 |
18 |
12 |
M 45.1 |
SQ |
| 9472 D 10 |
3/8 |
10 |
1 |
2 |
10 |
-- |
-- |
10 |
-- |
-- |
15 |
AL |
BN |
27.1 |
18 |
12 |
M 45.1 |
SQ |
| 9472 D 15 |
1/2 |
12 |
1.14 |
2 |
10 |
-- |
-- |
10 |
-- |
-- |
15 |
AL |
BN |
27.1 |
18 |
12 |
M 45.1 |
SQ |
| *ONLY SQ. COIL AVAILABLE |
|
|
| ELECTRICAL REFERENCE |
| Coil Type |
Power Consumption & Watt Rating |
Class Of
Insulation |
Protection |
| A.C. |
D.C. |
VA
Inrush |
VA
Holding |
Watts |
| M 45.1 SQ |
25 |
18 |
12 |
H |
C |
GP/WP IP.-67 |
| M 45.1 RD |
25 |
18 |
12 |
H |
C |
GP/WP IP.-67 |
| M 45.1 FLP IIB / FLP IIC |
25 |
18 |
12 |
H |
C |
IS 2148 Group IIA, IIB, IIC
IS 13947 PartI IP 67
IS 4012 Dustproof / IS 4013 Dusttight |
|
| |
| DIMENSION (IN MM) |
Catalogue
Number |
Pipe Size
(Inch) |
Constr.
Ret. |
A |
B |
C |
D |
M |
ØN |
ØP |
H |
Weight
Kgs.* |
| 9470 D 06 |
1/4 |
26.1 |
75 |
140 |
50 |
64 |
28 |
6.3 |
8 |
6 |
0.973 |
| 9470 D 10 |
3/8 |
26.1 |
114 |
183 |
76 |
92 |
39 |
7.0 |
10 |
8 |
2.623 |
| 9470 D 15 |
1/2 |
26.1 |
114 |
183 |
76 |
92 |
39 |
7.0 |
10 |
8 |
2.623 |
| 9472 D 06 |
1/4 |
27.1 |
75 |
140 |
50 |
64 |
28 |
6.3 |
8 |
6 |
1.506 |
| 9472 D 10 |
3/8 |
27.1 |
114 |
170 |
76 |
92 |
39 |
7.0 |
10 |
8 |
2.946 |
| 9472 D 15 |
1/2 |
27.1 |
114 |
170 |
76 |
92 |
39 |
7.0 |
10 |
8 |
2.946 |
|
| *Weight with SQ enclosure only, using Aluminium bodies; ask AVCON for other weights |
| |
CONSTRUCTION REF. NO. 26.1

CONSTRUCTION REF. NO. 27.1
 |
 |
Valve fitted with M45 RD GP coil-
General purpose enclosure as per IP-20

Valve fitted with M45 RD coil-
Waterproof metallic enclosure as per IS 13947 Part I IP-67
Valve fitted with M45 FLP IIB / FLP IIC coil-
Flameproof metallic enclosure as per IS 2148
 |
|
| |
Catalogue
Number |
Pipe Size
(Inch) |
Constr.
Ref. |
E (RADIALLY) |
F |
G (APPROX.) |
| RD GP |
RD GP |
FLP |
RD GP |
RD WP |
FLP |
RD GP |
RD WP |
FLP |
| 9470 D 06 |
1/4 |
26.1 |
60 |
96 |
96 |
48 |
62 |
80 |
127 |
135 |
205 |
| 9470 D 10 |
3/8 |
26.1 |
60 |
96 |
96 |
48 |
62 |
80 |
170 |
178 |
248 |
| 9470 D 15 |
1/2 |
26.1 |
60 |
96 |
96 |
48 |
62 |
80 |
170 |
178 |
248 |
| 9472 D 06 |
1/4 |
27.1 |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
-- |
| 9472 D 10 |
3/8 |
27.1 |
60 |
96 |
96 |
48 |
62 |
80 |
157 |
165 |
235 |
| 9472 D 15 |
1/2 |
27.1 |
60 |
96 |
96 |
48 |
62 |
80 |
157 |
165 |
235 |
|
| |
| Note: |
Technical specifications details & dimensions are subject to change without prior notice.