Home > Gas Produts > FG |
| |
|
Filters for Filteration of Fuel, Gas or Combustion Air,
when Supplying to
Gas Burning System or
Gas Consuming
Applications, Type FG |
DATA SHEET
FG |
|
| |
|
FEATURES :
- For protection against blockage of devices connected downstream.
- Very high throughput & high purification efficiency.
- Easy replacement of filter pads.
- Minimal pressure drop across the filter.
- Design in accordance with DIN3386.
|
| |
| TECHNICAL SPECIFICATIONS : |
| Body |
Aluminium Silicon Alloy for Model FG 15-150. |
| Filter Element |
Size 50 Micron, polypropylene fleece. |
| Size |
15, 25 mm BSP/ NPT (F) as per DIN 2999.
FG 40 to 150- Flanged construction as per ANSI B16.5 CI. 150RF or DIN 2501-C, PN 16, inlet plug 1/8" NPT, outlet plug 1/8" NPT, test points on cover. |
| Fluids |
Compatibility for gas in accordance with DIN DVGW Code of practice G260/1 can be used on air, Natural gas, LPG, Bio-gas. |
| Operating Pressure |
4 to 6 bar up to size 150 mm. |
| Operating Temperature |
(-) 5° C to (+) 80° C. |
| Ambient Temperature |
Maximum 80° C. Keep minimum distance of 20 mm from surrounding walls. |
|
NOTE :
- The installation can be carried out in to horizontal or vertical pipe line.
Authorized person must make installation. Check everywhere with soap film or leakage.
- Give maximum pressure 1.2 times of recommended maximum inlet pressure.
Exceeding this pressure, may result in bursting of the device.
- Standard filter pads are available in multiple of 10 for sizes up to 50 mm and in multiple of 5 for sizes 65mm and above. Use only genuine filter pads supplied by AVCON.
|
|

|
|
|
| SPECIFICATION TABLE : |
| BSP SCREWED DIMENSIONS |
| Model |
Size |
End
Connections |
Dimensions |
Flange |
Drilling |
Approx.
Weight
Kgs. |
 |
| L |
D |
H1 |
H2 |
D2 |
K |
D2 |
No. of Holes |
| mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
| FG 15 |
15 |
Rp 1/2 |
92 |
88 |
70 |
33 |
-- |
-- |
-- |
-- |
0.4 |
| FG 20 |
20 |
Rp 3/4 |
92 |
88 |
70 |
33 |
-- |
-- |
-- |
-- |
0.4 |
| FG 25 |
25 |
Rp 1 |
135 |
134 |
73 |
44 |
-- |
-- |
-- |
-- |
0.8 |
| ANSI TYPE FLANGE DIMENSIONS |
| FG 40A |
40 |
40 |
256 |
182 |
75 |
63 |
127 |
98 |
16 |
4 |
4.0 |
| FG 50A |
50 |
50 |
250 |
182 |
75 |
63 |
152 |
121 |
19 |
4 |
4.2 |
| FG 65A |
65 |
65 |
250 |
182 |
98 |
96 |
178 |
140 |
19 |
4 |
5.2 |
| FG 80A |
80 |
80 |
330 |
262 |
118 |
88 |
191 |
152 |
19 |
4 |
8.0 |
| FG 100A |
100 |
100 |
350 |
262 |
125 |
120 |
229 |
191 |
19 |
8 |
9.3 |
| FG 150A |
150 |
150 |
470 |
355 |
175 |
170 |
279 |
241 |
22 |
8 |
25.0 |
| DIN TYPE FLANGE DIMENSIONS |
| FG 40F |
40 |
40 |
256 |
182 |
75 |
63 |
150 |
110 |
18 |
4 |
4.0 |
| FG 50F |
50 |
50 |
250 |
182 |
75 |
63 |
165 |
125 |
18 |
4 |
4.2 |
| FG 65F |
65 |
65 |
250 |
182 |
98 |
96 |
185 |
145 |
18 |
4 |
5.5 |
| FG 80F |
80 |
80 |
330 |
262 |
118 |
88 |
200 |
160 |
18 |
8 |
9.6 |
| FG 100F |
100 |
100 |
350 |
262 |
125 |
120 |
220 |
180 |
18 |
8 |
11.5 |
| FG 150F |
150 |
150 |
470 |
355 |
175 |
170 |
285 |
240 |
23 |
8 |
25.0 |
|
|
|
| VOLUMETRIC FLOW DIAGRAM |
 |
 |
| SPECIFIC GRAVITY : |
| Natural Gas |
0.62 |
| Town Gas |
0.45 |
| LP Gas |
1.56 |
| Air |
1.0 |
|
|
| |
Attention :
When reading the diagram, operating cubic meters must be applied. The
pressure loss as read must be multiplied with the absolute pressure in bar
(excess pressure +1). This is to take the density fluctuations in to considerations.
THE PRESSURE DROP MUST NOT EXCEED 10 mbar. |
|
Example :
Excess Gas Rresssure: 4 bar , Operating Flow Rate 150 M³/hr of Natural Gas.
Filter chosen from the diagram : DN 65, the pressure drop read is 1.5 mbar. REAL PRESSURE DROP : 5 X 1.5 mbar =7.5 mbar. The real pressure drop is less than 10 millibar, therefore, correct size filter has been chosen. |
|
|
| |
| Note: |
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON. |
| |
|
|
|
|
|
|
|
|
|