Home > Gas Produts > SG |
| |
|
2/2-Way Direct Acting, Solenoid Valves, Normally Closed, Energised to Open
for gas & Air Application |
DATA SHEET
SG |
|
| |
|
FEATURES :
- Gas safety valve group ‘A’ in accordance with DN 3391/3
- Operating pressures 0 to 200 mbar, 0 to 360 mbar
- Long life design
- Internationally approved designs
- Robust, maintenance free, leakage free construction
- Fast opening or slow opening or adjustable initial opening
- Fast closing
- Large flow rate
- Fitted with flow adjustment device
- Low pressure loss through valve
- Available with opening speed adjustment damper
- Few models with single limit switch for position indication or proof of closure/opening.
|
| |
APPLICATION :
For protection, regulation and control of air and gas supply to gas burner/gas devices. |
| TECHNICAL SPECIFICATIONS : |
| Valve Body |
AISI Alloy cast, Pressure die-cast or gravity die cast |
| Valve Seat |
Buna Nitrile, on special request 'Viton'. |
| Magnectic construction |
430F. |
| Operating Pressure |
Refer to the specification table |
| Operating Temperature |
(-)20° to (+)60°C |
| Opening time |
SG..N without damping unit, fast opening~ 0.5 Sec. SG..L with damping unit, slow opening approx. 10Sec. |
| Closing time |
Less than 1 second |
| Switching frequency |
Arbitary |
| Coil protection |
IP-54 according to IS-2147. |
| Power factor |
1. |
| Coil insulation |
Class "F" |
| Standard Voltages |
110/220/240V +10% / -5%, 50Hz;24V +10% /-15% DC.
Coils on AC voltage (24 VAC excluded) are fed through protective circuit and rectifier. For 24V AC protective external protective circuit with rectifier must be provided. For 24V DC external protective circuit must be provided. |
| Power Consumption |
Will be in accordance with specification table. Power consumption does not change during pick-up and holding operation. |
| Duty Cycle |
100% |
| Fuse |
Max. 6.3 Amperes with anti surge protection. |
| Cable Entry |
Valves provided with coupler plug as per DIN 43650. |
| Cable Gland |
PG 11 for size 15 to 25 NB, Pg 13.5 for size 40 to 100NB |
| Fluids |
All gases in accordance with DVGW Code of practice G260/1 Natural gas, LPG, Methane, Bio-gas(special construction required), air or any other inert gas. |
|
|
|
|
|
 |
|
|
|
INSTALLATION INSTRUCTION :
- While installing the valve in the pipe work do not use Solenoid portion as a leaver. Use suitable holding device for the valve.
- Remove pipeline strain by installing suitable flexible joints.
- Read pressure loss and flow rate for the valve from the flow diagram. However valves can be also chosen by determining Kv value.
 |
P [ kg/m³ ]; ∆p [ milibar ]; ↓[ m³ /hr ]
(Conversion of SI Units) 1 milibar = 100Pa |
- Fix all valves in horizontal pipeline, keeping Solenoid vertical and upright.
- Housing must not touch its surrounding walls. Keep minimum 20mm distance.
|
|
For Regulators With Flanged Connection,
Flanged Bolts, Nuts and Washers Can
Be Supplied. |
 |
|
| |
| SELECTION TABLE : |
| SG |
Type |
| 40 |
Size |
| R/F/A |
Connection |
| 02 |
Maximum inlet pressure |
| L |
Damping Unit |
| T |
Voltage 15, 20, 25, 40 |
| 3 |
Terminal box |
| 1 |
Test Plug |
| *D |
|
| *S |
Closed Position Indicator |
| *M |
Suitable for Bio Produced methane |
| *V |
Seat Material |
| (*) IF NOT APPLICABLE THIS LETTERS IS OMITTED, i.e. THE NEXT LETTER MOVES ONE UP |
|
 |
 |
|
|
| TABLE 1 : FOR SCREWED END CONNECTION VALVES 200mbar |
| TYPE |
DN |
Dimensions |
Max.
Press
Gr. A
CI. 1 |
∆p=
1mbar
of air |
Kv
**** |
p |
|
p |
Weight |
Weight(1) |
| L |
H1 |
H2 |
H3 |
E |
(1) |
220V
110V
24V
AC |
(1) |
240 V
AC |
(1) |
| |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mbar |
m³/hr |
m³/hr |
VA/W |
VA/W |
VA/W |
VA/W |
kg*** |
kg*** |
| SG 15 R 02 |
15 |
71 |
161 |
112 |
24 |
56 |
185 |
200 |
3.8 |
4.3 |
32 |
38 |
38 |
38 |
1.26 |
1.46 |
| SG 20 R 02 |
20 |
91 |
175 |
126 |
33 |
61 |
208 |
200 |
8 |
9.1 |
31 |
42 |
37 |
42 |
1.91 |
2.11 |
| SG 25 R 02 |
25 |
91 |
175 |
126 |
33 |
61 |
208 |
200 |
10 |
11.4 |
31 |
42 |
37 |
42 |
2.10 |
2.30 |
| TABLE FOR SCREWED END CONNECTION VALVES 360mbar |
| SG 15 R 03 |
15 |
71 |
161 |
112 |
24 |
56 |
185 |
360 |
3..8 |
4.3 |
32 |
31 |
38 |
37 |
1.26 |
1.46 |
| SG 20 R 03 |
20 |
91 |
175 |
126 |
33 |
66 |
208 |
360 |
8 |
9.1 |
36 |
42 |
42 |
42 |
2.25 |
2.45 |
| SG 25 R 03 |
25 |
91 |
175 |
126 |
33 |
66 |
208 |
360 |
10 |
11.4 |
36 |
42 |
42 |
42 |
2.25 |
2.45 |
|
Note:
(1) Model with Damper
*** Model with position indicator
**** Refer to formulate to obtain kv |
| TABLE 2 : FOR FLANGED END CONNECTION VALVES |
| MODEL - SGXXA WITH ANSI FLANGES |
|
MODEL - SGXXF WITH DIN FLANGES |
| Type |
DN |
L |
Dimensions |
Flange |
No.
of
holes |
Max
Press
Gr.A
CI.1 |
∆p=
1mbar
of air |
Kv*** |
p
220V
110V
24V
AC |
P
240 V |
Weight |
| OD |
H1 |
H2 |
H3 |
D2 |
K |
d2 |
| |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
mbar |
m³/hr |
m³/hr |
VA/W |
VA/W |
kgs* |
| ANSI TYPE FLANGE DIMENSIONS FOR 200mbar |
| SG 40 A 02 |
40 |
200 |
128.5 |
279.5 |
204.5 |
50.5 |
127 |
98 |
16 |
4 |
130 |
24 |
27.3 |
67 |
75 |
7.5 |
| SG 50 A 02 |
50 |
230 |
156.5 |
291 |
216 |
62 |
152 |
121 |
19 |
4 |
130 |
37 |
42.1 |
73 |
86 |
9.6 |
| SG 65 A 02 |
65 |
290 |
183.5 |
303 |
228 |
74 |
178 |
140 |
19 |
4 |
130 |
57 |
64.8 |
85 |
99 |
15.8 |
| SG 80 A 02 |
80 |
310 |
210 |
404 |
329 |
103 |
191 |
152 |
19 |
4 |
130 |
90 |
102.3 |
105 |
125 |
25 |
| SG 100 A 02 |
100 |
350 |
210 |
428 |
353 |
110 |
229 |
191 |
19 |
8 |
130 |
142 |
161.5 |
158 |
187 |
41 |
| ANSI TYPE FLANGE DIMENSIONS FOR 360mbar |
| SG 40 A 03 |
40 |
200 |
128.5 |
279.5 |
204.5 |
50.5 |
127 |
98 |
16 |
4 |
360 |
24 |
27.3 |
73 |
86 |
8.8 |
| SG 50 A 03 |
50 |
230 |
156.5 |
291 |
216 |
62 |
152 |
121 |
19 |
4 |
360 |
37 |
42.1 |
85 |
99 |
14.3 |
| SG 65 A 03 |
65 |
290 |
183.5 |
393 |
318 |
74 |
178 |
140 |
19 |
4 |
360 |
57 |
64.8 |
105 |
125 |
21.6 |
| SG 80 A 03 |
80 |
310 |
210 |
404 |
329 |
103 |
191 |
152 |
19 |
4 |
360 |
90 |
102.3 |
158 |
187 |
36 |
| SG 100 A 03 |
100 |
350 |
210 |
428 |
353 |
110 |
229 |
191 |
19 |
8 |
360 |
142 |
161.5 |
158 |
187 |
50 |
| DIN TYPE FLANGE DIMENSIONS FOR 200mbar |
| SG 40 F 02 |
40 |
200 |
128.5 |
279.5 |
204.5 |
50.5 |
150 |
110 |
18 |
4 |
130 |
24 |
27.3 |
67 |
75 |
7.5 |
| SG 50 F 02 |
50 |
230 |
156.5 |
291 |
216 |
62 |
165 |
125 |
18 |
4 |
130 |
37 |
42.1 |
73 |
86 |
9.6 |
| SG 65 F 02 |
65 |
290 |
183.5 |
303 |
318 |
74 |
185 |
145 |
18 |
4 |
130 |
57 |
64.8 |
85 |
99 |
15.8 |
| SG 80 F 02 |
80 |
310 |
210 |
404 |
329 |
103 |
200 |
160 |
18 |
8 |
130 |
90 |
102.3 |
105 |
125 |
25 |
| SG 100 F 02 |
100 |
350 |
210 |
428 |
353 |
110 |
220 |
180 |
18 |
8 |
130 |
142 |
161.5 |
158 |
187 |
41 |
| DIN TYPE FLANGE DIMENSIONS FOR 360mbar |
| SG 40 F 03 |
40 |
200 |
128.5 |
279.5 |
204.5 |
50.5 |
150 |
110 |
18 |
4 |
360 |
24 |
27.3 |
73 |
86 |
8.8 |
| SG 50 F 03 |
50 |
230 |
156.5 |
291 |
216 |
62 |
165 |
125 |
18 |
4 |
360 |
37 |
42.1 |
85 |
99 |
14.3 |
| SG 65 F 03 |
65 |
290 |
183.5 |
393 |
318 |
74 |
185 |
145 |
18 |
4 |
360 |
57 |
64.8 |
105 |
125 |
21.6 |
| SG 80 F 03 |
80 |
310 |
210 |
404 |
329 |
103 |
200 |
160 |
18 |
8 |
360 |
90 |
102.3 |
158 |
187 |
36 |
| SG 100 F 03 |
100 |
350 |
210 |
428 |
353 |
110 |
220 |
180 |
18 |
8 |
360 |
142 |
161.5 |
158 |
187 |
50 |
Note:
* With Slow Opening Valve + 0.5 kg. for the damping unit,
version with position indicator +0.2 kg.
*** Withot damping unit, without position indicator, without flow rate restrictor. |
|
|
VOLUMETRIC FLOW DIAGRAM
VOLVES WITH LOW INLET PRESSURE |
 |
| SPECIFIC GRAVITY : |
| Natural Gas |
0.62 |
| Town Gas |
0.45 |
| LP Gas |
1.56 |
| Air |
1.0 |
|
|
Note:
when reading operating cubic meter in
the diagram, without converting to m³/hr
(n), the pressure loss as read, is to be
multiplied with the absolute pressure in
bar (positive pressure in bar). |
| |
| Note: |
Technical specifications details & dimensions are subject to change without prior notice.
Dimensions in the table are approximate subject to final confirmation by AVCON. |
| |
|
|
|
|
|